11. Check ribbon cable from logic board back to control board for damage such as cracks or
abrasions and ensure it is not in contact with any sharp edges or moving parts.
12. Remove pump from trough and drain out and clean out any sludge remaining in trough.
Dismantle water distributor and clean with bottle brush taking note that all water holes are
clean and unobstructed. Reassemble and refit distributor and water pump.
13. Sanitize storage bin as per manufacturers specifications.
14. Start machine & check all machine signal functions, ensuring board lights operate when
curtains, high / low switches are activated.
15. Check purge on fill cycle and adjust if required. (See Page 3)
16. After second ice drop check thickness and adjust if required. (See Page 3)
17. Replace machine panels.
18. Clean down all external surfaces.
19. Replace ice into storage bin.
Note: Using none-approved cleaning medium may void ice making plate warranty


 